IEC / en 60529, the dust and water proofing test

summary




According to the Test Specification IEC / en 60529, the dust and water proofing test requirements of the products shall be met. As long as the product needs to prevent solid objects, such as arms, fingers, metal rods, metal wires, even dust or liquid (water) from entering the product, there is a set of standard test equipment, methods, time and judgment criteria.




The full name of IEC / en 60529 standard is degrees of protection provided by enclosure (IP code), which means the protection level provided by the product enclosure. IP is the abbreviation of international protection, which means the internationally recognized protection level. At present, more and more countries adopt it. Only in the United States and Canada, the national standards such as ul50 and CSA are still used for dust prevention and waterproof.




Generally speaking, most of the product standards of IEC or En will make some modifications to the conditions of IEC / en 60529, such as test conditions or judgment standards, in order to meet the requirements of their special products. These standards, such as IEC / en 60598 lighting products, IEC / en 60335 household appliances, IEC / en 60558 power supply standards, and even IEC / en 60950 information product standards, often have requirements for dust-proof and waterproof tests.




The products need dustproof and waterproof test. Most of them are used in outdoor or humid environment, such as lamps, advertising materials, air-conditioning products, bathroom supplies, washing machines, swimming pool supplies, sauna supplies, fish tank supplies, power supplies of the above products, and even information products have increasingly emphasized the function of dustproof and waterproof.




Dust proof and waterproof test standard:




Meaning of IP code: IP N1, N2, y, Z




The first number (N1): it can be 0, 1, 2, 3, 4, 5, 6 or X, representing the ability to prevent solid objects from entering (dust prevention).




The second number (N2): can be 0, 1, 2, 3, 4, 5, 6, 7, 8 or X, representing the ability to prevent liquid from entering (waterproof).




Additional first letter (y): can be h, m, s, W, representing additional protection conditions.




The additional second letter (z): can be a, B, C, D, representing the ability to protect the contact with dangerous parts.




power.




First number




Test significance




Test capability




0




Not required







one




50mm diameter sphere




50N




two




12.5mm diameter sphere




30N




three




2.5mm diameter metal rod




3N




four




1.0mm diameter wire




1N




five




Dust chamber, with or without negative pressure







six




Dust chamber with negative pressure







Second number




Test significance




Water volume or depth




Test time:




0




Not required










one




Vertical drip test




1mm/min




10min




two




Drip test with inclination of 15 degrees




3mm/min




2.5min for each slope




three




Water spray test (60 degrees)




0.07 L / min (per well)




10min




four




Splash test (180 degrees)




0.07 L / min (per well)




10min




five




Water column test




12.5 L/min




1min/m2,≥3min




six




Strong water column test




100L/min




1min/m2,≥3min




seven




Short immersion test




The top is 15cm from the water surface or the bottom is 1m from the water surface




30min




eight




Continuous immersion test




Individual provisions, but stricter than 7




>30 min




Judgment after test




Generally, if there is no special provision in the product standard, the requirements for ip5x dust test are:




Talc powder shall not accumulate or enter the product. If any other dust enters, it may endanger the normal operation of the product or product safety.




Talc powder shall not be allowed to enter, which may reduce the creepage distance, which does not meet the safety requirements.




Generally, if there are no special provisions in the product standard, the requirements for ip6x dust test are:




No dust shall enter the enclosure.




Generally, if there is no special provision in the product standard, the requirements for ipx1-ipx6 waterproof test are:




The normal operation of the product shall not be affected.




Do not endanger product safety.




No water shall enter the coil that contacts the live part or is not waterproof.




There shall be no ponding at the cable terminal or entering the cable.


--